indicated first, followed by the heat transfer medium for the indoor heat exchanger (see Table 1).
Table 1 — Most common types of units
Heat transfer medium
Outdoor heat exchanger Indoor heat exchanger Classification
Air Air Air/air heat pump or air cooled air
conditioner
Water Air Water/air heat pump or water
cooled air conditioner
Brine Air Brine/air heat pump or brine
cooled air conditioner
Air Water Air/water heat pump or air cooled
liquid chilling package
Water Water Water/water heat pump or water
cooled liquid chilling package
Brine Water Brine/water heat pump or brine
cooled chilling package
EN 14511-1:2004 (E)
11
Index
A
air conditioner .......................................................... 2.1
application rating conditions ................................ 2.42
B
basic multi-split system......................................... 2.43
brine ........................................................................ 2.39
C
close control air conditioner ................................... 2.4
coefficient of performance, COP........................... 2.30
comfort air conditioner or heat pump .................... 2.3
control cabinet air conditioner................................ 2.5
D
defrost mode .......................................................... 2.33
defrost period ......................................................... 2.34
E
effective power input, PE ....................................... 2.27
energy efficiency ratio, EER.................................. 2.28
exhaust air .............................................................. 2.18
G
glide......................................................................... 2.38
H
heat pump................................................................. 2.2
heat recovery.......................................................... 2.11
heat recovery capacity........................................... 2.25
heat recovery efficiency, HRE............................... 2.51
heat recovery heat exchanger............................... 2.14
heat recovery liquid chilling package................... 2.10
heat rejection capacity........................................... 2.24
heat transfer medium............................................. 2.15
heating capacity, PH ............................................... 2.23
I
indoor heat exchanger........................................... 2.12
L
latent cooling capacity, PL ..................................... 2.21
liquid chilling package............................................. 2.9
M
modular heat recovery multi-split system............ 2.46
modular multi-split system.................................... 2.45
multiple circuit multi-split system ........................ 2.44
O
operating cycle with defrost.................................. 2.35
operating range ...................................................... 2.31
outdoor air .............................................................. 2.16 (责任编辑:admin)